SAGE Journals Online
Advertisement
Sign In to gain access to subscriptions and/or personal tools.

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Advertisement

Sign In to gain access to subscriptions and/or personal tools.
Journal of Intensive Care Medicine
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Nanji, A. A.
Right arrow Articles by Hinberg, I.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Nanji, A. A.
Right arrow Articles by Hinberg, I.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Other

Decentralized Clinical Chemistry Testing: Quality of Results Obtained by Residents and Interns in an Acute Care Setting

Amin A. Nanji, MD, FRCP

Departments of Pathology and Laboratory Medicine, University of Ottawa and Ottawa General Hospital, Department of Laboratory Medicine, Ottawa General Hospital, 501 Smyth Rd, Ottawa, Ontario, K1H 8L6 Canada.

Raymond Poon, PhD

Bureau of Radiation and Medical Devices, Health Protection Branch, Ottawa, Ontario, Canada

Irwin Hinberg, PhD

Bureau of Radiation and Medical Devices, Health Protection Branch, Ottawa, Ontario, Canada

We evaluated the quality of results obtained for near- patient testing by residents and interns (MDs) using desk-top analyzers. The instruments evaluated were the Reflotron analyzer, the Seralyzer, the Vision analyzer, and the Kodak DT60 analyzer. Low- and high-concen trations of control materials were used for precision studies. Results obtained by MDs were compared with those obtained by a trained technologist for comparison studies. The range of precision obtained by MDs was 4.6 to 6.6% for the Reflotron analyzer, 3.6 to 20.7% for the Seralyzer, 1.7 to 5.3% for the Vision analyzer, and 2.7 to 13% for the Kodak DT60 analyzer. The range of correla tion coefficients for each of the analyzers was 0.980 to 0.994 for the Reflotron analyzer, 0.763 to 0.933 for the Seralyzer, 0.989 to 0.999 for the Vision analyzer, and 0.987 to 0.999 for the Kodak DT60. The percentage of results for each of the analyzers when the results ob tained by MDs were more than 10% different from the trained technologist's results were 17.3% for the Reflo tron, 44% for the Seralyzer, 0% for the Vision, and 17% for the Kodak DT60. The discrepancies between MD and the trained technologist's results are related to the complexity of the instruments used.

Journal of Intensive Care Medicine, Vol. 3, No. 5, 272-277 (1988)
DOI: 10.1177/088506668800300510


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
J Intensive Care MedHome page
D. H. Wong
Decentralized Clinical Chemistry Testing in the Intensive Care Unit: A Concept Whose Time Has Come?: Wong DH. Decentralized clinical chemistry testing in the in tensive care unit: a concept whose time has come? J Intensive Care Med 1988;3:239-240
J Intensive Care Med, September 1, 1988; 3(5): 239 - 240.
[PDF]



Advertisement